  • LA314/314H Technical Specifications

    [LeCroy]

    Main Features

    • 4 Channels
    • Up to 500ps/div Time Resolution
    • High-Speed Auto Setup
    • Cursor Measurements
    • Event and Burst Trigger Modes
    • Full TV Trigger with clamping
    • Save and Recall Panel settings
    • Frequency Counter
    • High-Input Offset Range
    • High Intensity CRT
    • Power for FET Probes

    Specifications

    • DC - 470 MHz, 4-CH, 10 traces: Four channels up to 470 MHz are available, with CH1 and CH2 boasting the widest frequency range with highest sensitivity (2mV/div). The fastest sweep speed is 500 ps/div.
    • Input offset function: Suitable for the observation of small signals superimposed on large signals. The DC input offset function features an offset equivalent to ±500 div. max, which can be applied to CH1 or CH2.
    • Counter measurement function: Built-in 5 digit counter for frequencies up to 470 MHz.
    • Save/Recall up to 256 panel settings: Just turn the FUNCTION knob to recall panel setups. Stores up to 256 settings in memory.
    • Power for FET Probe: Dedicated power supplies for 2 FET probes. Controls DC offset voltage of each probe as well.
    • TV/HDTV Synchronization: TV triggering is available for NTSC, PAL, (SECAM) and HDTV. Field (EVEN, ODD, BOTH) and line select functions are included.
    • TV Clamp Function: Easy observation of TV video signals with fluctuating average voltage. Back porch level of composite signals is fixed to ground level for display.
    • Typical Applications:
      • Video, especially VCRs and TVs.
      • Data recording, finding servo anomalies, glitches and intermittent phenomena in the disk-drive head- signals.
      • Eye patterns (for DVDs) in optical disk measurements.
      • Wide-bandwidth noise measurements on magneto optical disks.
      • Radar/Lidar burst measurements.
      • Eye pattern measurements on ATM 155 Mbps signals.
    • Display:
      • CRT: 6-inch rectangular, internal graticule (8 x 10 div) meshless CRT
      • Accelerating voltage: Approximately 20 kV
    • Vertical Deflection System:
      • Mode: CH1, CH2, CH3, CH4, ADD (CH1 + CH2), ALT, CHOP
      • Channel 1, 2 Sensitivity: 2 mV/div - 5 V/div ±2%, 11 step (1-2-5)
      • Fine Adjuster: 2 mV/div - 12.5 V/div continuously variable
      • Bandwidth (-3dB):
        • Model LA314H: 470 MHz (5 mV/div - 50 mV/div); 440 MHz (2 mV/div, 100 mV/div - 5 V/div)
        • Model LA314: 400 MHz (2 mV/div - 5 V/div)
      • BW limiter: 20 MHz and 100 MHz selectable
      • VSWR: Less than 1.35:1 over DC - 400 MHz (with 50 ohm input)
      • Rise time:
        • Model LA314H: Approx. 745 ps @ 20 mV/div
        • Model LA314: Approx. 875 ps
      • Input coupling: AC, DC, GND
      • Input RC: Hi-Z input: 1 Mohm ±1.5%||16 pf ±2pf, Lo-Z input: 50 ohm ±1%.
      • Maximum input voltage: 1 Mohm input: ±400 V max.; 50 ohm input: 5 V RMS
      • Polarity switching: CH2 only
      • Probe sensors: 1:1, 1:10, 1:100 detection possible
      • Offset voltage variable range:

        Offset voltageVertical axis range
        ±1 V 2mV/div - 50 mV/div
        ±10 V 0.1 V/div - 0.5 V/div
        ±100 V 1 V/div - 5 V/div

      • Channel 3, 4 Sensitivity: 100 mV, 500 mV/div
      • Accuracy: ±3% (+10°C - +35°C)
      • Bandwidth (-3dB): 400 MHz
      • Rise time: Approx. 875 ps (bandwidth x rise time = 0.35)
      • Input coupling: AC, DC
      • Input RC: Direct: 1 Mohm ±1.5% || 16 pF+3pF, when using the probe (SS-082R): 10 Mohm ±2% || 13pF ±2pF
      • Maximum input voltage: ±400 V max
      • Probe sensors: 1:1, 1:10, 1:100 detection possible
    • Triggering
      • A Triggering:
        • Sources: CH1, CH2, CH3, CH4
        • Coupling: AC, DC, HF-REJ, LF-REJ
        • Polarity: ±
        • TV sync - Line selection: NTSC: 1 - 525H; PAL (SECAM): 1 - 625H; HDTV: 1 - 1125H
      • B Triggering:
        • Sources: CH1, CH2, CH3, CH4, LINE
        • Coupling: AC, DC, HF-REJ, LF-REJ
        • Polarity: ±
        • Event Delay: Count: Setting range: 1 - 65535 maximum count freq.: 50 MHz
        • Burst: Time setting range: 0.15 µs - 9.99s
        • Auto setup: Input channels: CH1, CH2, Freq. range: 50 Hz - 100 MHz
    • Horizontal Deflection System Display A, ALT, B, X-Y
      • A sweep:
        • Mode: AUTO, NORM, SINGLE
        • Sweep time: 5 ns/div - 500 ms/div ±2%, 25-step (1-2-5)
        • Fastest sweep time: 500 ps/div
        • Fine adjuster: 5 ns/div - 1.5 s/div
      • B sweep:
        • Delay:
          • Triggered delay: CH1, CH2, CH3, CH4
          • Continuous delay: B delayed by A
        • Sweep time: 5 ns/div - 20 ms/div ±2%, 21 step (1, 2, 5)
        • Delay time range: 0.2 div - 10.2 div;
        • Accuracy: + (setting value x 0.005) + (sweeptime x 0.1) -55 ns
        • Magnifier (MAG): 10 times
        • Accuracy: ±5% (+10°C - +35°C)
    • X-Y Operation:
      • X axis: CH1
      • Y axis: CH1, CH2, CH3, CH4, ADD
      • Accuracy: ±2% (+10°C - +35°C)
    • CH2 Out:
      • Output voltage: 20 mV/div ±30%
      • Frequency output: DC - 200 MHz (50 ohm load)
      • Output resistance: 50 ohm ±20%
    • Utilities:
      • Save/Recall Function:
        • Number of panel setups: 256 max
        • Comments: 12 characters max
      • Modulation (Z-axis):
        • Minimum modulation voltage: 0.5 Vp-p
        • Polarity: Positive (dark)/negative (bright)
        • Frequency range: DC - 5 MHz
        • Max. input voltage: 40 V
      • Calibrator
        • Waveform: Square
        • Repetitive frequency: 1 kHz
        • Accuracy: ±0.1%
        • Output voltage: 0.6 V
        • Accuracy: ±1%
      • Power for FET probes
        • Voltage: 2 each +12 V outlets for 2 FET probes, offset control available
      • CTR Readout:
        • Counter
          • Display digits: 5 digits shown at all times
          • Accuracy: ±0.01%
          • Frequency measurement range: 2 Hz - 400 MHz
        • Cursor Measurement
          • Voltage axis: 2
          • Time axis: 2
          • Time difference: deltaT
          • Voltage difference: deltaV
          • delta T & delta V can be simultaneously measured
    • Power:
      • Voltage range: AC 90 V - 250 V
      • Frequency range: 48 Hz - 440 Hz
      • Power consumption: 120 VA max
    • Dimensions and Weight:
      • Dimensions: Approx. 320W x 160H x 420L mm
      • Weight: approx. 8.5 kg (19.8 lbs)
    • Approvals:
      • EMC: Comforms to EN55011 and EN50082-2.
      • Low Voltage: Conforms to EN61010-1 Installation Category II, Pollution Degree 2.
    • Safety:
      • UL and cUL Approved: Comfirms to UL3111-1 Confirms to Canadian Standard CSA-22.2, No. 1010.1-92