    [LeCroy]

    General Features

    • Compact and Portable: At 6.6 lbs (3 kg), this compact scope is easy to carry and fits very easily onto crowded workbenches.
    • High-Speed Sampling Rate and Long Memory: Operates at 500 MS/s sampling rate with 100 MHz analog bandwidth. Each channel has a long 100 kpoints acquisition memory.
    • High Accuracy: Vertical accuracy is within 2% and horizontal accuracy is 50 ppm (0.005%).
    • Cursor Measurements: Two cursors (two vertical or two horizontal) let you measure voltage difference (delta V), time difference (delta t), frequency (1/delta t), and V at t for a specific waveform.
    • Auto Copy: Display or waveform data can be output automatically to a specified device (built-in printer, ATA card, or floppy disk).
    • Simple to Use, yet Powerful: Features a variety of automatic measurements, triggers, floppy, internal printer, and interfaces to external devices.
    • Great Value: Lots of information at an amazingly low cost!
    • Screenshots:
      [Screen Shot] [Screen Shot] [Screen Shot]
      Cursors and parameters. Help when you need it. Troubleshoot signal
      interruptions.
    • Easy-to-Use Menu Selection: Just turn the function knob to select a menu item, then press to activate it.
    • Help Menu: Explains the various menu functions. Useful for beginners or for advanced users needing to know what a particular function does.
    • Event Trigger: Wide range of triggers, including event triggers (count/burst/extra/missing) and TV triggers (NTSC/PAL/SECAM).
    • Hardware Five-Digit Frequency Counter: Input signal frequency can be shown in five digits. No more guessing about signal aliasing.
    • 13 Automatic Measurements: All the basic automatic functions required for common measurements are provided, assuring quick, accurate results and improving working efficiency.
    • 25 GS/s Equivalent Sampling: Using the equivalent sampling method, the time resolution is increased up to 40 ps (equivalent to 25 GS/s). Pre-trigger information is available.
    • Input/Output Devices:
      [PCMCIA Slot] [Printer] [Floppy Drive]
      ATA flash card. Internal printer. Floppy drive.

    Main Specifications

    • Acquisition System: (Common to CH1, CH2)
      • Sensitivity: 2 mV/div ­ 10 V/div (1-2-5 steps) (0.8 mV/div zoomed)
      • Bandwidth: DC ­ 100 MHz (frequency cutoff is 10 Hz for AC coupling)
      • Max single-shot sampling rate: 500 MS/s
      • Equivalent sampling mode: 25 GS/s
      • Peak detect: 500 MS/s
      • Resolution: 8-bit
      • Acquistion Memory: Short ­ 5 kpts/ch; long ­ 100 kpts/ch
      • Storage Modes: Normal, equivalent sampling, peak detect, average, roll
    • Triggering System:
      • Modes: Auto, Normal Single
      • Sources: CH1, CH2, EXT
      • Types: Edge, Event, TV
      • Event trigger: Count, Burst, Missing, Extra
    • Timebase System:
      • Time/div range: 5 ns ­ 50 s/div (1-2-5 steps)
      • Roll Mode: 500 MS ­ 1000 s/div
    • Display Functions:
      • Display: 5.7" (145 mm) backlit LCD display
      • X-Y display: X = CH1, Y = CH2
      • Help function: Available on screen in reverse video
    • Waveform Storage: (Save and Recall)
      • Media: ATA card, floppy disk (3.5")
      • Data type: Setup, waveform
      • Record format: Binary and ASCII formats are available for waveform data.
      • Comment: Text comments can be appended to waveform files.
      • Auto copy: Waveforms can be automatically copied to a storage device after each trigger.
    • Math and Measurement Functions:
      • Cursors: delta V, delta t, 1/delta t, V at t
      • Parameters: Tr, Tf, Vrms, Vmean, etc. (total 13 items)
      • Arithmetic functions: +, -, x
      • Frequency counter: Five display digits, 1 Hz ­ 100 MHz frequency range
    • Other Features:
      • Auto setup: Automatically setup V, H range and trigger for repetitive signal
      • Interface: RS-232C
      • Data output: Centronics
      • Built-in printer: Line thermal printer, roll print available
      • Floppy, ATA card: Output format TIFF, BMP
      • Centronics formats: DPU-414, ESC-P09, ESC-P24, PC-PR201, TIFF, BMP
    • Power Supply:
      • Voltage range: AC 100 ­ 240 V
      • Power consumption: 90 VA max (with built-in printer operation)
    • Dimensions and Weight:
      • Dimensions (width, height,length): 8.4" x 6.7" x 6.5" (214 mm x 170 mm x 166 mm)
      • Weight: Approx. 6.6 lbs (3.0 kg) excluding accessories
    Back to the Literunner product page.